Usage

Usage

The client is async — all network operations must run inside an asyncio event loop. Commands are plain functions in givenergy_modbus.client.commands that return lists of requests, which you send via one_shot_command or execute.

Coming from the givenergy-modbus-async fork? See Migrating from the async fork for the lifecycle change (detect() + load_config()/refresh() replacing refresh_plant) and the attribute renames.

Basic example

import asyncio
from givenergy_modbus.client.client import Client
from givenergy_modbus.client import commands
from givenergy_modbus.model import TimeSlot
from givenergy_modbus.model.inverter import Model

async def main():
    client = Client(host="192.168.99.99", port=8899)
    await client.connect()

    # Detect the topology once, then read the config banks (needed for slot_map).
    # load_config()/refresh() raise RefreshPartiallySucceeded / RefreshFailed on
    # read failures — see "Polling the plant" below for handling.
    await client.detect()
    await client.load_config()
    plant = client.plant

    # Write configuration to the device
    await client.one_shot_command(commands.set_charge_target_enabled(80))
    await client.one_shot_command(
        commands.set_charge_slot(1, TimeSlot.from_components(0, 30, 4, 30), plant.inverter.slot_map)
    )
    await client.one_shot_command(commands.set_mode_dynamic())

    print(plant.inverter_serial_number)
    print(plant.inverter.model)                 # e.g. Model.HYBRID
    print(plant.inverter.enable_charge_target)
    print(plant.inverter.charge_slot_1)         # TimeSlot instance
    print(plant.inverter.slot_map)              # SlotMap for this model

    if plant.batteries:
        print(plant.batteries[0].serial_number)
        print(plant.batteries[0].soc)

    await client.close()

asyncio.run(main())

Polling the plant

Run detect() once after connecting, then drive your own poll loop over the primitives: load_config() reads the HR configuration banks, refresh() reads the IR measurement banks. Both return the populated Plant on full success, and raise on read failures:

  • RefreshPartiallySucceeded — some reads failed, some succeeded. The data that did arrive is on exc.plant; exc.failures lists the dropped reads (device address, request type, base register) and exc.cause is an ExceptionGroup of the raw errors. This is the one chance to use the partial data — cache it, surface it, count it — before deciding how to treat the gaps. How to treat them is the consumer's policy, not the library's.
  • RefreshFailed — every read failed; the link is effectively dead and there is no partial data. Treat the device as unavailable.

Both share the base RefreshError, so a consumer that doesn't care to distinguish can catch that.

from givenergy_modbus.exceptions import RefreshFailed, RefreshPartiallySucceeded

async def main():
    client = Client(host="192.168.99.99", port=8899)
    await client.connect()
    await client.detect()

    while True:
        try:
            plant = await client.refresh()
        except RefreshPartiallySucceeded as exc:
            plant = exc.plant                  # use what we did collect
            # ...consumer policy: log exc.failures, bump a counter, etc.
        except RefreshFailed:
            plant = None                       # mark unavailable; maybe reconnect

        if plant is not None:                  # full or partial success
            print(f"SOC: {plant.batteries[0].soc}%")
        await asyncio.sleep(15)

Client.watch_plant() and Client.refresh_plant() are deprecated and will be removed in 3.0 — own the loop as above. They now also propagate RefreshPartiallySucceeded / RefreshFailed.

Power register measurement points

The instantaneous "grid" power registers on a single-phase Hybrid do not all measure the same physical point — the shared grid prefix is misleading. There are two distinct nodes: the inverter's own AC terminal (where it connects to the consumer unit's busbar) and the external grid CT (the clamp at the meter boundary).

   PV ─DC─┐                       ┌─► house load            p_load_demand  (IR42)
          ├─[INVERTER]─AC─busbar──┤
   Bat ─DC┘   terminal            └─► grid CT ─► meter      p_grid_out     (IR30)
        p_grid_out_ph1 (IR24)          boundary
        p_grid_apparent (IR43)
        i_grid_port (IR58)
Attribute Node Notes
p_grid_out_ph1 (IR24) Inverter AC terminal real power onto the busbar; +ve = delivering. Not the grid CT despite the name
p_grid_apparent (IR43) Inverter AC terminal apparent power (VA) pairs with IR24 → sensible power factor
i_grid_port (IR58) Inverter AC terminal current pairs with IR24/IR43
p_grid_out (IR30) External grid CT net flow +ve = export, −ve = import; the meter boundary
p_load_demand (IR42) House load at the busbar independently sensed, not derived from IR24−IR30
p_battery (IR52) Battery DC port +ve = discharge, −ve = charge

On a single-phase unit p_grid_out_ph1 and p_grid_out are related but distinct (per-phase inverter throughput vs net grid flow), so inverter_terminal = load + grid_export (IR24 = IR42 + IR30) holds at the busbar. These node assignments were established empirically against a single-phase Hybrid Gen 1; the three-phase layout (whether p_grid_out aggregates the inverter phases or stays a separate CT register) is not yet confirmed.

Directional power accessors

If you just want non-negative, sign-resolved power for display, prefer the computed accessors over the raw signed registers — they read the same on single- and three-phase: battery_charge_power / battery_discharge_power (split p_battery by direction) and grid_import_power / grid_export_power (split the net grid register). Each returns the magnitude in its direction and 0 otherwise, so a consumer needn't handle the sign.

Tuning timeouts and retries

refresh, load_config and one_shot_command all accept the same three knobs:

  • timeout — how long to wait for each response. Defaults: refresh 2.0s, load_config 2.0s, one_shot_command 1.5s.
  • retries — number of additional attempts after a timeout. Defaults: refresh 1, load_config 3, one_shot_command 0.
  • retry_delay (default 0.5s) — seconds to wait between a timed-out attempt and the next.

refresh defaults to timeout=2.0, retries=1 because the inverter serialises requests: when other clients (GivTCP, the vendor app, Predbat) poll the same unit, a tighter budget loses the race and produces spurious "register read failed" timeouts even though the device is responsive (#132). If you own the bus exclusively and want genuine failures surfaced faster, pass a tighter timeout/retries.

The retry delay exists because some inverters exhibit multi-second silent windows where they stop responding to anything; firing the retry immediately tends to land it inside the same window, accomplishing nothing. The 0.5s default matches what GivTCP independently arrived at and works for most hardware. If you observe sustained timeout clusters longer than ~1s in your logs, try increasing it; if you need fail-fast behaviour for an interactive command, pass retry_delay=0.

Charge and discharge slots

The number of available slots depends on the inverter model. The inverter command API (see below) reads slot_map from the instance so you don't have to thread it through:

inverter = plant.inverter

# Set slot 1 (available on all models)
await client.one_shot_command(
    inverter.set_charge_slot(1, TimeSlot.from_components(0, 30, 4, 30))
)

# Set slot 5 (only available on extended-slot models)
await client.one_shot_command(
    inverter.set_charge_slot(5, TimeSlot.from_components(12, 0, 14, 0))
)

# Clear slot 3
await client.one_shot_command(inverter.reset_charge_slot(3))

If you call the underlying primitives directly (commands.set_charge_slot(...)), you must pass inverter.slot_map explicitly — see the Available commands reference further down.

Models and their slot counts:

Models Charge slots Discharge slots
HYBRID_GEN1, HYBRID_GEN2, AC, POLAR 2 2
HYBRID_GEN3 (ARM fw ≤ 302) 2 2
HYBRID_GEN3 (ARM fw > 302), ALL_IN_ONE, HYBRID_GEN4, HYBRID_HV_GEN3 10 10
Three-phase (HYBRID_3PH, AC_3PH) 10 10

Inverter command API

The recommended entry point is the inverter instance itself:

inverter = plant.inverter

await client.one_shot_command(inverter.set_charge_target_enabled(80))
await client.one_shot_command(inverter.set_enable_discharge(True))
await client.one_shot_command(inverter.set_charge_slot(1, my_timeslot))

The inverter knows its own slot_map, so slot setters don't need it threaded through. The base _InverterCommands mixin is composed onto both SinglePhaseInverter and ThreePhaseInverter; _ThreePhaseCommands (also composed onto ThreePhaseInverter) overrides the methods where single-phase and three-phase register addresses differ.

Three-phase inverters additionally carry the _ThreePhaseCommands mixin (marker: ✦ three-phase), so set_ac_charge, set_force_charge, set_force_discharge, and set_battery_reserve_soc are reachable as instance methods on ThreePhaseInverter only:

if isinstance(inverter, ThreePhaseInverter):
    await client.one_shot_command(inverter.set_force_charge(True))

AC-limit commands (set_battery_*_limit_ac) and pause-mode commands (set_battery_pause_mode, set_pause_slot_*) remain on commands.* only — their model-vs-firmware applicability hasn't yet been confirmed against wire data (see #75).

EMS command API

EMS commands target the EMS plant controller — a peer device of the inverter, not the inverter itself — so they live on the Ems instance returned by plant.ems rather than on plant.inverter:

ems = plant.ems
if ems is not None:  # None on non-EMS plants
    await client.one_shot_command(ems.set_ems_plant(True))
    await client.one_shot_command(ems.set_ems_charge_slot(1, my_timeslot))
    await client.one_shot_command(ems.set_export_slot(1, my_timeslot))

EMS slots use a fixed three-slot layout at HR(2044–2071) — there's no slot_map parameter. EMS commands are tagged ▣ ems in the tables below.

Available commands

All commands live in givenergy_modbus.client.commands and return list[TransparentRequest] for passing to one_shot_command or execute. The inverter API above delegates to these; using them directly remains supported for tests and lower-level integration.

Stability

Both surfaces are supported within the 2.x line. The high-level mixin APIs (inverter.set_* on SinglePhaseInverter / ThreePhaseInverter, ems.set_* on Ems) are recommended; commands.* is the primitive layer that the mixins delegate to. There is no plan to deprecate commands.* within 2.x — the two are not duplicate paths but two layers of the same stack. If individual primitives turn out to be persistent footguns when used without an inverter (e.g. routing the wrong slot_map), they may be @deprecated case-by-case.

Where each command lives

Surface Composed onto Marker in tables below
_InverterCommands SinglePhaseInverter, ThreePhaseInverter (none — inherited base surface)
_ThreePhaseCommands ThreePhaseInverter only ✦ three-phase
_EmsCommands Ems only ▣ ems
commands.* only (not exposed as mixin method) ⛔ commands-only

An unmarked row means the method is available on both inverter types. On ThreePhaseInverter, _ThreePhaseCommands overrides set_enable_charge, set_battery_soc_reserve, set_mode_dynamic, set_charge_target_enabled, disable_charge_target, and the slot setters to use the correct three-phase registers (HR 1112, 1109, 1111, 1113–1121).

Charging

Function Description Surface
set_charge_target_enabled(soc) Enable charging and stop when SOC reaches soc% (4–100). (set_charge_target is a deprecated alias)
set_charge_target_soc(soc) Set just the charge-target SOC (4–100), leaving the enable bits untouched
disable_charge_target() Remove SOC limit, target 100%
set_enable_charge(enabled) Enable or disable charging
set_battery_charge_limit(val) Charge power limit (0–50%)
set_battery_charge_limit_ac(val) AC charge power limit (1–100%) ⛔ commands-only
set_shallow_charge(val) Set shallow charge threshold (deprecated — use set_battery_soc_reserve) ⛔ commands-only

Discharging

Function Description Surface
set_enable_discharge(enabled) Enable or disable discharging
set_battery_discharge_limit(val) Discharge power limit (0–50%)
set_battery_discharge_limit_ac(val) AC discharge power limit (1–100%) ⛔ commands-only
set_battery_soc_reserve(val) Minimum SOC to maintain (4–100%)
set_battery_power_reserve(val) Battery power reserve (4–100%)

Time slots

Function Description Surface
set_charge_slot(idx, timeslot, slot_map) Set charge slot idx (1-based)
set_charge_slot_start(idx, t, slot_map) Set just the start of charge slot idx (or None to clear that end)
set_charge_slot_end(idx, t, slot_map) Set just the end of charge slot idx (or None to clear that end)
reset_charge_slot(idx, slot_map) Clear charge slot idx
set_discharge_slot(idx, timeslot, slot_map) Set discharge slot idx (1-based)
set_discharge_slot_start(idx, t, slot_map) Set just the start of discharge slot idx (or None to clear that end)
set_discharge_slot_end(idx, t, slot_map) Set just the end of discharge slot idx (or None to clear that end)
reset_discharge_slot(idx, slot_map) Clear discharge slot idx
set_export_slot(idx, slot) Set export slot idx (1–3), or clear if None ▣ ems
set_export_slot_start(idx, t) Set just the start of export slot idx ▣ ems
set_export_slot_end(idx, t) Set just the end of export slot idx ▣ ems
set_export_priority(priority) Set surplus-power dispatch priority (ExportPriority: BATTERY_FIRST, GRID_FIRST, LOAD_FIRST) — AC-coupled only
set_enable_eps(enabled) Enable or disable Emergency Power Supply (EPS) mode — AC-coupled only
set_battery_pause_mode(val) Set pause mode (BatteryPauseMode: DISABLED, PAUSE_CHARGE, PAUSE_DISCHARGE, PAUSE_BOTH) ⛔ commands-only
set_pause_slot(slot) Set battery pause time slot (or None to clear) ⛔ commands-only
set_pause_slot_start(t) Set just the start of the battery pause slot ⛔ commands-only
set_pause_slot_end(t) Set just the end of the battery pause slot ⛔ commands-only
set_ems_plant(enabled) Enable/disable EMS plant control ▣ ems
set_ems_charge_slot(idx, timeslot) Set EMS plant charge slot idx (1–3), or clear if None ▣ ems
set_ems_charge_slot_start(idx, t) Set just the start of EMS charge slot idx ▣ ems
set_ems_charge_slot_end(idx, t) Set just the end of EMS charge slot idx ▣ ems
set_ems_discharge_slot(idx, timeslot) Set EMS plant discharge slot idx (1–3), or clear if None ▣ ems
set_ems_discharge_slot_start(idx, t) Set just the start of EMS discharge slot idx ▣ ems
set_ems_discharge_slot_end(idx, t) Set just the end of EMS discharge slot idx ▣ ems
set_ems_charge_target_soc(idx, soc) EMS charge slot idx target SOC (0–100%) ▣ ems
set_ems_discharge_target_soc(idx, soc) EMS discharge slot idx target SOC (0–100%) ▣ ems
set_ems_export_slot(idx, timeslot) Set EMS plant export slot idx (1–3), or clear if None ▣ ems
set_ems_export_slot_start(idx, t) Set just the start of EMS export slot idx ▣ ems
set_ems_export_slot_end(idx, t) Set just the end of EMS export slot idx ▣ ems
set_ems_export_target_soc(idx, soc) EMS export slot idx target SOC (0–100%) ▣ ems
set_ems_export_power_limit(watts) EMS plant export power limit (watts) ▣ ems

EMS plant scheduling commands (set_ems_*) target the EMS controller's own plant-config registers (HR 2040-2071) and use a fixed three-slot layout, so — unlike the inverter charge/discharge setters — they take no slot_map. Use them only against an EMS device (plant.capabilities.is_ems); they have no effect on a standalone inverter. Export slots themselves (set_export_slot) are shared with the EMS export schedule.

The whole-slot setters (set_charge_slot, set_discharge_slot, set_pause_slot, set_export_slot) write both endpoints in one call. The _start / _end variants each write a single register and exist for callers (notably Home Assistant) whose UI models start and end as independent entities. Either form is fine — they produce the same wire frames when used in sequence.

The charge and discharge variants require slot_map as a non-default argument — always pass plant.inverter.slot_map so the call routes to the right registers for the inverter type. Defaulting it would mean a slot index that's valid on one inverter family silently targeting wrong registers on another.

Operating modes

Function Description Surface
set_mode_dynamic() Dynamic/Eco mode — maximise self-consumption
set_mode_storage(discharge_slot_1, discharge_slot_2, discharge_for_export) Storage/timed discharge mode
set_discharge_mode_max_power() Set battery to discharge at max power
set_discharge_mode_to_match_demand() Set battery to match load demand
set_ac_charge(enabled) Enable or disable AC charging ✦ three-phase
set_force_charge(enabled) Force battery charge ✦ three-phase
set_force_discharge(enabled) Force battery discharge ✦ three-phase
set_battery_reserve_soc(val) Battery reserve SOC (HR 1078, "Battery Reserve %", 4–100%) ✦ three-phase

Battery calibration

Function Description Surface
set_calibrate_battery_soc(val) Recalibrate SOC estimation: 0 = Stop, 1 = Start (default), 3 = Charge Only

System

Function Description Surface
set_active_power_rate(target) Max inverter output as % of rated capacity
set_system_date_time(dt) Set inverter clock
set_enable_rtc(enabled) Enable Real Time Clock (persists settings to EEPROM)
set_inverter_reboot() Restart the inverter

Serialisation

All model objects are pydantic v2 models:

plant.inverter.model_dump()       # dict
plant.inverter.model_dump_json()  # JSON string

Register caches

A RegisterCache (plant.register_caches[device_address]) round-trips two ways:

from givenergy_modbus.model.register_cache import RegisterCache, to_compact, parse_compact

cache.json()                   # JSON string of {register: value}
RegisterCache.from_json(text)  # inverse

to_compact({0x32: cache})      # compact hex probe-dump (str), human-legible
parse_compact(text)            # inverse → {device_address: RegisterCache}

json()/from_json() are single-cache; to_compact/parse_compact are multi-device and emit the same compact hex format the CLI's probe --compact produces, so a register dump pasted into a bug report can be reconstructed and replayed offline.

Sharing a redacted dump

Before sharing a cache or a whole plant, strip the serial numbers. cache.redact_serials() returns a copy with serial registers date-redacted (family prefix + manufacture week kept, unit digits zeroed — the same scheme as the capture-frame redaction below), and plant.redact() redacts the whole plant. Combine with the serialisers above for a share-safe export.

Capturing frames for bug reports

Client.capture_frames(sink, duration=60.0) tees raw TX/RX bytes to a caller-supplied sink callable while the normal refresh loop continues — useful when a bug report needs to include the actual wire bytes. Inverter and dongle serial numbers are redacted by the library before the sink is invoked: only the digits are zeroed; the prefix and model letter survive because they carry diagnostic signal.

The library does the redaction; persistence and format are the caller's choice. A minimal file-based capture looks like:

from datetime import UTC, datetime

from givenergy_modbus.exceptions import RefreshError

with open("capture.txt", "w") as f:
    def write_line(direction, frame):
        ts = datetime.now(UTC).isoformat(timespec="microseconds")
        f.write(f"{ts} {direction} {frame.hex()}\n")
        f.flush()
    async with Client("inverter.local", 8899) as client:
        await client.detect()

        async def poll():
            while True:
                try:
                    await client.refresh()
                except RefreshError:  # ignore partial/total failures for this capture demo
                    pass
                await asyncio.sleep(5)

        await asyncio.gather(
            poll(),
            client.capture_frames(write_line, duration=60),
        )

Only one capture may run on a Client at a time — starting a second raises RuntimeError.

Persisting detection state across restarts

Client.detect() is the slow part of a cold start — it probes for BCUs, meters and battery devices across address ranges where most slots are empty, each probe waiting for its own timeout. The returned PlantCapabilities describes the topology that was actually found, and can be persisted by the calling application to skip the empty-slot scan on next start.

import json
from pathlib import Path

caps = await client.detect()
Path("~/.givenergy-caps.json").expanduser().write_text(json.dumps(caps.to_dict()))

On next start, hand the previously-captured caps back via prior=:

import json
from pathlib import Path

from givenergy_modbus.exceptions import PlantTopologyMismatch
from givenergy_modbus.model.plant import PlantCapabilities

stored = json.loads(Path("~/.givenergy-caps.json").expanduser().read_text())
prior = PlantCapabilities.from_dict(stored)

try:
    caps = await client.detect(prior=prior)
except PlantTopologyMismatch as exc:
    # Hardware changed since `prior` was captured. Either fall back to a cold
    # detect, prompt the user, or accept the new layout explicitly.
    caps = await client.detect()  # cold rescan

Hinted mode is strict: each address listed in prior is still probed, but the empty-slot sweep is skipped. If anything in prior fails to confirm — or the inverter's device_type has changed — detect() raises PlantTopologyMismatch (carrying both prior and actual) and leaves client.plant.capabilities as None. The application chooses the recovery policy. Library does no file I/O itself; storage location and lifecycle are entirely the caller's responsibility.

The serialised form is stable and includes a schema_version field:

{
  "schema_version": 1,
  "device_type": "HYBRID",
  "inverter_address": "0x11",
  "meter_addresses": ["0x01"],
  "lv_battery_addresses": ["0x32", "0x33"],
  "bcu_stacks": []
}

inverter_address is 0x11 for every model. (AC and HYBRID_GEN1 hardware additionally answers at 0x31 — a facade over the same register file — which older library versions used as their polling address.) LV battery pack #1 lives at 0x32, additional packs at 0x330x37. Previously persisted state reloads unchanged and self-heals: a stored 0x31 keeps working against the hardware facade until the next detect() re-derives 0x11, and a pre-existing 0x32 (the oldest mapping, where the inverter shared the battery address) surfaces as a one-off PlantTopologyMismatch.