Writable registers

Writable registers

This document covers the full write surface of the GivEnergy Modbus library: which holding registers can be written, at what tier, through which API entry point, and what is known about their effect.

Provenance

The primary source is the GivEnergy app v4.0.7 "Direct Control" tab, which exposes the manufacturer's own writable-register map for end users (post–cloud-portal retirement) and a separate installer-login surface — the full holding-register write map (460 entries) and per-model telemetry-kind table are cross-referenced against it. The v4.1.6 hybrid Modbus RTU protocol document (2024-10-30) provides supplementary context; a parsed inventory lives in docs/reference/registers/.

GivEnergy entered administration in 2025. No further firmware or documentation updates are expected, which makes the GivEnergy apps the most authoritative register reference likely to exist.

Write tiers

The library enforces two independent gates around every write.

Gate 1 (client): Client.one_shot_command() validates that each request is in the per-model safe set before dispatching. Client.installer_command() extends that set to include INSTALLER_WRITE_REGISTERS, but is never used by one_shot_command().

Gate 2 (PDU): WriteHoldingRegisterRequest.ensure_valid_state() — called automatically during encode — checks the register against the appropriate allow-list. A request constructed without installer=True is rejected if its register is not in WRITE_SAFE_REGISTERS; one constructed with installer=True is rejected if it is not in INSTALLER_WRITE_REGISTERS. The two sets are disjoint by design.

Tier Entry point Register set Typical use
Standard one_shot_command() WRITE_SAFE_REGISTERS Charge slots, SOC limits, mode switches, EMS scheduling
Installer — config installer_command() INSTALLER_WRITE_REGISTERS (non-destructive) Grid-protection limits, battery commissioning, hardware enables
Installer — destructive installer_command() INSTALLER_WRITE_REGISTERS (destructive group) Factory reset, energy-total reset, black-start

Installer tier — read before use

Installer registers control grid-safety parameters, hardware operating modes, and factory configuration. Incorrect values can leave a site operating outside grid-code tolerances, prevent battery charging, or — for the destructive group — wipe all installer configuration irreversibly.

  • Always obtain a baseline read of the current register value before writing.
  • Apply changes incrementally and verify telemetry after each step.
  • The destructive command helpers (restore_factory_defaults, reset_energy_totals, three_phase_factory_reset, enable_black_start) require confirm=True and will raise ValueError without it. This is intentional — there is no undo.
  • The original motivation for exposing this tier: with GivEnergy in administration there is no longer a field-engineer path to correct a factory-misconfigured inverter. Use it accordingly — sparingly, deliberately, with a known target value in hand.

Standard write surface

Accessed via Client.one_shot_command(). All registers below are in WRITE_SAFE_REGISTERS (givenergy_modbus/pdu/write_registers.py).

Charge / discharge enable and targets

HR Field name Description Range / values
20 enable_charge_target Enable AC charge upper % limit bool
96 enable_charge Enable battery charging bool
59 enable_discharge Enable battery discharging bool
116 charge_target_soc AC charge upper SOC % limit 4–100 %
110 battery_soc_reserve Discharge floor / SOC reserve 4–100 %
111 battery_charge_limit Battery charge power limit 0–100 % of rated
112 battery_discharge_limit Battery discharge power limit 0–100 % of rated
114 battery_discharge_min_power_reserve Minimum discharge power reserve 4–100 %
29 battery_calibration_stage SOC force-adjust 0 (Stop), 1 (Start), 3 (Charge Only)

Charge slots 1–10

HR (start / end) Field names Notes
94 / 95 charge_slot_1_start / _end HHMM format
31 / 32 charge_slot_2_start / _end
246 / 247 charge_slot_3_start / _end
249 / 250 charge_slot_4_start / _end
252 / 253 charge_slot_5_start / _end
255 / 256 charge_slot_6_start / _end
258 / 259 charge_slot_7_start / _end
261 / 262 charge_slot_8_start / _end
264 / 265 charge_slot_9_start / _end
267 / 268 charge_slot_10_start / _end

Discharge slots 1–10

HR (start / end) Field names Notes
56 / 57 discharge_slot_1_start / _end
44 / 45 discharge_slot_2_start / _end
276 / 277 discharge_slot_3_start / _end
279 / 280 discharge_slot_4_start / _end
282 / 283 discharge_slot_5_start / _end
285 / 286 discharge_slot_6_start / _end
288 / 289 discharge_slot_7_start / _end
291 / 292 discharge_slot_8_start / _end
294 / 295 discharge_slot_9_start / _end
297 / 298 discharge_slot_10_start / _end

Battery mode and scheduling

HR Field name Description Notes
27 battery_power_mode Enable eco mode bool
50 active_power_rate Active power rate 0–100 %
163 inverter_reboot Restart inverter write 100; non-damaging
166 enable_rtc Real-time control bool
199 enable_inverter_parallel_mode Enable parallel mode bool
299 discharge_target_soc_10 DC discharge 10 lower SOC % limit 0–100 %
331 force_off_grid Force off-grid bool; see note below

HR331 — Force off-grid

This is a sustained islanding state, not a momentary reboot. A stuck write leaves the site off-grid with no auto-recovery. Bounded boolean; admitted to the standard tier because the app exposes it to end users, but treat with care at call sites.

System time

HR Description
35 System time: year
36 System time: month
37 System time: day
38 System time: hour
39 System time: minute
40 System time: second

Use set_system_date_time(dt) rather than writing these individually.

AC-coupled config (AC / All-in-One models)

Gated on PlantCapabilities.has_ac_config_block inside one_shot_command().

HR Field name Description Range
311 export_power_priority Export power priority 0=Load / 1=Battery / 2=Grid
313 inverter_charge_power_pct Inverter charge power % 1–100 %
314 inverter_discharge_power_pct Inverter discharge power % 1–100 %
317 enable_eps Enable EPS bool
318 battery_pause_mode Pause battery BatteryPauseMode enum
319 battery_pause_slot_start Pause slot start HHMM
320 battery_pause_slot_end Pause slot end HHMM

HR313 / HR314 floor at 1, not 0

Writing 0 to HR313 or HR314 returns an error on AC hardware (confirmed via wire capture). The range floor is 1 for AC inverters. DC-coupled models keep a 0-floor for HR111 / HR112.

Three-phase

HR Field name Description
1005 real_time_control_3ph Real-time control (mirrors HR166)
1078 battery_reserve_pct_3ph Battery reserve %
1108 discharge_power_rate_3ph Discharge power rate
1109 discharge_down_to_pct_3ph Discharge down-to %
1110 charge_power_rate_3ph Charge power rate
1111 charge_up_to_pct_3ph Charge up-to %
1112 enable_ac_charge_3ph Enable AC charge
1113 / 1114 ac_charge_1_start / _end AC charge slot 1
1115 / 1116 ac_charge_2_start / _end AC charge slot 2
1118 / 1119 dc_discharge_1_start / _end DC discharge slot 1
1120 / 1121 dc_discharge_2_start / _end DC discharge slot 2
1122 enable_force_discharge_3ph Enable force discharge
1123 enable_force_charge_3ph Enable force charge

EMS plant-level scheduling (HR2040–2071)

HR Description Notes
2040 Enable plant EMS control bool
2044–2046 EMS discharge slot 1 (start / end / SOC limit)
2047–2049 EMS discharge slot 2
2050–2052 EMS discharge slot 3
2053–2055 EMS charge slot 1 (start / end / SOC limit)
2056–2058 EMS charge slot 2
2059–2061 EMS charge slot 3
2062–2064 EMS export slot 1 (start / end / SOC limit)
2065–2067 EMS export slot 2
2068–2070 EMS export slot 3
2071 EMS export power limit Installer/DNO — not user-writable via app

Use the set_ems_* helpers in commands.py rather than writing these directly.

Smart load time slots (HR554–573)

HR (start / end) Description
554 / 555 Smart load slot 1
556 / 557 Smart load slot 2
558 / 559 Smart load slot 3
560 / 561 Smart load slot 4
562 / 563 Smart load slot 5
564 / 565 Smart load slot 6
566 / 567 Smart load slot 7
568 / 569 Smart load slot 8
570 / 571 Smart load slot 9
572 / 573 Smart load slot 10

Misc / hardware-gated

HR Field name Description Notes
104 Enable battery self-heating Hardware/batch-gated: write may be rejected per-unit
172 Enable manual battery heater Likely hardware-gated like HR104
5010 Restart hardware Non-damaging; same class as HR163
5014 Enable calculated load

Installer write surface

Accessed via Client.installer_command(). All registers below are in INSTALLER_WRITE_REGISTERS and are inaccessible through one_shot_command(). See the safety note at the top of this document.

AC grid protection — voltage and frequency limits

Three-level trip scheme confirmed against the GivEnergy Installer app: trip (HR63–70) is the tighter/faster band, reconnect (HR71–78) the looser outer band, and grid (HR79–82) the steady-state grid band. HR83 is the 10-minute mean voltage protection. Converters for this block are inferred from the three-phase parallel block (HR1018–1042); unverified on live single-phase hardware.

The corresponding Def fields are in givenergy_modbus/model/inverter.py and can be read back after a poll. Bounds-validating helpers (set_v_ac_low_limit_trip, etc.) are available for all 21 registers; each requires installer=True and confirm=True. The legacy _1/_2/_3 field names remain as deprecation-warning aliases.

HR Field name Description Unit / range Setter
63 v_ac_low_limit_trip AC undervoltage trip threshold V × 0.1; 0–500 set_v_ac_low_limit_trip
64 v_ac_high_limit_trip AC overvoltage trip threshold V × 0.1; 0–500 set_v_ac_high_limit_trip
65 f_ac_low_limit_trip AC underfrequency trip threshold Hz × 0.01; 40–70 set_f_ac_low_limit_trip
66 f_ac_high_limit_trip AC overfrequency trip threshold Hz × 0.01; 40–70 set_f_ac_high_limit_trip
67 t_ac_low_voltage_trip Undervoltage trip time s × 0.01 set_t_ac_low_voltage_trip
68 t_ac_high_voltage_trip Overvoltage trip time s × 0.01 set_t_ac_high_voltage_trip
69 t_ac_low_freq_trip Underfrequency trip time s × 0.01 set_t_ac_low_freq_trip
70 t_ac_high_freq_trip Overfrequency trip time s × 0.01 set_t_ac_high_freq_trip
71 v_ac_low_limit_reconnect AC undervoltage reconnect threshold V × 0.1; 0–500 set_v_ac_low_limit_reconnect
72 v_ac_high_limit_reconnect AC overvoltage reconnect threshold V × 0.1; 0–500 set_v_ac_high_limit_reconnect
73 f_ac_low_limit_reconnect AC underfrequency reconnect threshold Hz × 0.01; 40–70 set_f_ac_low_limit_reconnect
74 f_ac_high_limit_reconnect AC overfrequency reconnect threshold Hz × 0.01; 40–70 set_f_ac_high_limit_reconnect
75 t_ac_low_voltage_reconnect Undervoltage reconnect time s × 0.01 set_t_ac_low_voltage_reconnect
76 t_ac_high_voltage_reconnect Overvoltage reconnect time s × 0.01 set_t_ac_high_voltage_reconnect
77 t_ac_low_freq_reconnect Underfrequency reconnect time s × 0.01 set_t_ac_low_freq_reconnect
78 t_ac_high_freq_reconnect Overfrequency reconnect time s × 0.01 set_t_ac_high_freq_reconnect
79 v_ac_low_limit_grid AC undervoltage grid-band threshold V × 0.1; 0–500 set_v_ac_low_limit_grid
80 v_ac_high_limit_grid AC overvoltage grid-band threshold V × 0.1; 0–500 set_v_ac_high_limit_grid
81 f_ac_low_limit_grid AC underfrequency grid-band threshold Hz × 0.01; 40–70 set_f_ac_low_limit_grid
82 f_ac_high_limit_grid AC overfrequency grid-band threshold Hz × 0.01; 40–70 set_f_ac_high_limit_grid
83 v_ac_10min_protect AC voltage 10-minute average protection V × 0.1; 0–500 set_v_ac_10min_protect

Grid import / anti-islanding

HR Field name Description Notes
101 Grid import limit (value) raw uint16
102 Grid import limit enabled bool; set_grid_import_limit_enabled()
115 Anti-islanding detection bool; set_anti_islanding_detection()

Battery commissioning

HR Field name Description Range / notes
174 Wake battery write 1
201 Restart battery write 1
308 battery_nominal_power Battery nominal power W; no app range — consult battery spec
309 battery_nominal_current Battery nominal current A; no app range
310 battery_max_charge_pct Battery max charge % 20–100 %; set_battery_max_charge_pct()

HR308–310 scale

Register addresses cross-referenced against the GivEnergy app v4.0.7. Scale and exact unit encoding are unconfirmed on live hardware — treat the raw value as uint16 until a confirming capture is available.

Plant and inverter operating config (AC block, HR300–359)

This block is polled on AC-coupled and All-in-One inverters (has_ac_config_block), so these registers are now decoded for read-back — a consumer can read the current value before issuing an installer write. The field names below are the getter fields in model/inverter.py. Scale/semantics are unconfirmed on live hardware (raw uint16 unless noted), but raw read-back is correct regardless. On non-AC/AIO models the block is not polled and these fields read None.

HR301 (plant_role) is decode-only — it is not in INSTALLER_WRITE_REGISTERS, so installer_command() will reject a write to it. It appears here only because it decodes from the same polled block; every other register in this table is installer-writable.

HR Field name Description Notes
300 enable_plant_mode Enable plant mode bool; set_enable_plant_mode()
301 plant_role Plant primary/secondary role selection read-only (decode-only; not installer-writable)
302 plant_meters Plant meters raw
303 overfrequency_load_drop_recovery_delay Overfrequency load drop recovery delay raw
305 mppt_operating_mode MPPT operating mode raw
306 connection_loading_slope Connection loading slope raw
307 eps_nominal_voltage EPS nominal voltage raw
312 underfrequency_add_load_delay Underfrequency add load delay raw
315 en50549_zero_current_lower_voltage_limit EN50549 zero-current static lower voltage limit raw
316 en50549_zero_current_upper_voltage_limit EN50549 zero-current static upper voltage limit raw
321 overfrequency_derating_start_point Overfrequency derating start point raw
322 enable_tariff_pricing_battery_logic Enable tariff pricing battery logic bool
323 import_price_battery_discharge_threshold Import price battery discharge threshold raw
324 import_price_battery_charge_threshold Import price battery charge threshold raw
325 export_price_battery_discharge_threshold Export price battery discharge threshold raw
326 underfrequency_derating_start_point Underfrequency derating start point raw
327 underfrequency_loading_slope Underfrequency loading slope raw
328 overfrequency_derating_stop_point Overfrequency derating stop point raw
329 enable_bms_ocv_calibration Enable BMS OCV calibration bool
330 gateway_power_off_setting Gateway power off setting raw
332 enable_micro_grid Enable micro grid bool; set_enable_micro_grid()
347 disable_leds Disable LEDs bool
348 lcd_screen_idle_timeout LCD screen idle timeout raw
349 lead_acid_battery_calibration_upper_limit Lead acid battery calibration upper limit raw
350 lead_acid_battery_calibration_lower_limit Lead acid battery calibration lower limit raw
351 inverter_operating_mode Inverter operating mode raw

EV charger (HR333–336)

HR Field name Description Range / notes
333 enable_ev_charger EV charger enable bool; set_enable_ev_charger()
334 ev_charger_import_limit EV charger import limit raw
335 ev_charger_reconnection_wait_time EV charger reconnection wait time raw
336 ev_charger_soc_limit EV charger SOC limit 0–100 %; set_ev_charger_soc_limit()

Fan, gateway, and communications

HR Description Notes
337 Enable fan bool
338 Fan speed raw
339 Enable gateway bool
340 BMS communication mode raw
341 N-PE relay toggle raw
342 AFCI setting raw

Generator (HR343–346)

HR Description Range / notes
343 Enable generator bool; set_enable_generator()
344 Generator start SOC 0–100 %; set_generator_start_soc()
345 Generator stop SOC 0–100 %; set_generator_stop_soc()
346 Generator charge power raw

Smart load — non-slot controls (HR540–553)

See the standard tier for the slot start/end times; these registers control the feature's enable state and operating thresholds.

HR Field name Description Range / notes
540 Enable smart load bool; set_enable_smart_load()
541 Smart load control SOC 50–100 %; set_smart_load_control_soc()
542 Enable general load bool
543 General load control SOC 50–100 %; set_general_load_control_soc()
544 Generator control SOC 10–90 %; set_generator_control_soc()
545 Generator voltage min raw
546 Generator voltage max raw
547 Generator frequency min raw
548 Generator frequency max raw
552 Smart load export power raw
553 Smart load delay time raw

Three-phase power quality and grid compliance

HR Description Notes
1048 Q lock-out power q_lock_out_power Def; raw uint16
1077 PV input mode pv_input_mode Def; raw uint16
1081–1087 QU curve points and reactive power limits raw
1102 Export limit (three-phase) raw
1103 Enable export limit (three-phase) bool; set_enable_export_limit_3ph()
1125 Enable LoRa bool
1126 Meter CT direction raw
1127–1129 Load shedding voltage limits and minimum active power % raw
1130 Import limit (three-phase) raw
1131 Enable import limit (three-phase) bool; set_enable_import_limit_3ph()
1144 Enable meter wiring detection bool
1149 Meter wiring detection state raw
1156 Safety function control word raw
1158–1165 Active power ratio, high/low points, QP lock in/out voltage, min PF raw

Dual-grid / plant

HR Description Notes
4001 Dual grid supply operational mode raw

Special commands (non-destructive)

HR Description Notes
5002 Send wake-up signal write 1
5005 Enable PV meter preset bool
5006 Enable AC meter preset bool
5007 Enable N-PE bool
5008 Enable CT auto configuration bool
5009 Enable auto address configuration bool
5011 Grid power limit raw
5012 AC overcurrent limit raw

Peak shaving / export-import control (EMS installer, HR20000+)

HR Description Notes
20000 Enable grid export limit bool; set_peak_shaving_export_limit_enabled()
20001 Grid export limit raw
20002 Enable peak shaving bool; set_peak_shaving_enabled()
20003 Peak shaving threshold raw
20020 Enable import limit bool
20021 Import limit threshold raw
20050 Peak shaving power raw
20051 Valley filling power raw

Peak-shaving polling (HR20000–20051)

The has_peak_shaving_block capability flag is currently False for all models, so no poll is issued for this range. The corresponding Def entries exist and will decode once a confirming live capture allows a model to be added to the capability set.

Destructive operations

These actions cannot be undone

Each helper below raises ValueError unless called with confirm=True. Read the docstring of each helper before use. Obtain the current register state beforehand; there is no rollback.

HR Helper Description
162 reset_energy_totals(confirm=True) Clear all lifetime energy counters
1016 three_phase_factory_reset(confirm=True) Three-phase factory reset (no meter reset)
5003 enable_black_start(confirm=True) Activate EPS black-start mode
5004 restore_factory_defaults(confirm=True) Wipe all installer config to factory defaults

Held-back registers

These registers appear in the GE app 4.0.7 writable map but are intentionally not admitted to either allow-list pending a bounds-validating set_* wrapper or additional field evidence.

HR App name Reason held back
479 DC Wind CVT Voltage Raw 16-bit voltage setpoint; no range guard — admit only with a validating command

Reconciliation status

The app 4.0.7 holding-register inventory (460 entries) is committed to docs/reference/registers/app_4.0.7_inventory.json. A diff against the library's live REGISTER_LUTs, WRITE_SAFE_REGISTERS and INSTALLER_WRITE_REGISTERS runs as a regression test in CI via scripts/audit_register_doc.py --app-source — both allow-lists are checked against the app surface, so neither standard nor installer write drift can land silently. The reconciliation stands at 390 matched / 70 app-only gaps, after decoding the polled installer-config block (HR300–351), the three-phase QU-curve / export-limit registers (HR1081–1087, HR1102–1103) and HR331. The remaining gaps are predominantly registers in blocks not admitted to the read poll (special commands HR5000+, peak-shaving HR20000+) or identity/serial registers that are document-only by design.