GivEnergy installer app — register & protocol reference

Companion to installer_1.154.3_inventory.json, a register & protocol reference cross-referenced against the GivEnergy Installer app (v1.154.3).

Why this exists

GivEnergy entered administration with no published Modbus specification. The values here are cross-referenced against the GivEnergy Installer app (v1.154.3), which exposes a more complete view of the register surface than the consumer app does (see app_4.0.7_inventory.json) — register maps with decode scales, named enums, the local-Modbus transport, the write path, and the destructive-operation set. Treat it as the most complete GivEnergy register reference available, pending hardware confirmation.

Transport & addressing

  • Dongle at 10.10.100.254:8899 over either a ws:// WebSocket or Bluetooth LE (service 000000ff…, characteristic ff05 = Modbus, ff01 = config/auth).
  • Framing: the GivEnergy 18-byte transparent frame (magic 0x5959 "YY", 10-char dongle serial), inner Modbus CRC-16 (init 0xFFFF, poly 0xA001, byte-swapped on wire).
  • Transport function codes: HEARTBEAT=1, TRANSPARENT=2, READ_DATALOG=3, WRITE_DATALOG=4, FAULT=5. Inner Modbus: FC03 (read holding), FC04 (read input), FC06 (write single), FC16 (write multiple — dev console only).

Device-address map (the authoritative version — cross-check Plant._getter_for_device_address):

Subsystem Address
Inverter / EMS 17 (0x11)
Meters 1–8
EMS version 33
PCS / managed inverters 35–42
BMS cluster 32 + clusterId
LV battery 49 + id
HV BMU (per module) 80–111 (0x50–0x6F)
HV BCU (per stack) 112+ (0x70+)
HV BAMS 144+ (0x90+)

The HV BMU band (0x50–0x6F) resolves the long-standing per-module decode question — see below.

Write model

Installer settings are written as FC06 single-register, fire-and-forget — no retry, no verify-by-reread, and crucially no commit/save step. SET_COMMAND_SAVE (HR1001) exists for read-back only and is never written; multi-write sequences just pace each write ~5 s apart. The write scale is the inverse of the decode divideBy (a register decoded ÷10 is written ×10), so the decode-scale metadata in the inventory doubles as the write-scale reference. Writability is decided in per-screen form code, not flagged on the register definitions.

Per-cell HV battery — the read recipe (resolves #265)

Per-cell HV voltages/temperatures are on the Modbus wire; prior probes missed them by sweeping the BCU band (0x70+) when the per-cell array lives one band lower on the BMU addresses.

  • FC04 (read input), device 0x50–0x6F (one per module), start register 60, count 60.
  • IR60–83 = CELL_VOLTAGE_1..24 — raw mV ÷ 1000 → V.
  • IR90–113 = MODULE_TEMPERATURE_1..24deci-°C ÷ 10, signed, 16-bit big-endian.
  • Topology counts: device 0xA0, IR60–64 = BAMS_COUNT / BCU_COUNT / BMU_COUNT / CELL_COUNT_PER_MODULE / TEMPERATURE_SENSOR_COUNT.

The library's old Bmu(base=120·k) decode was addressing the wrong device (a stride within the BCU cache), not the wrong offset. Wire-confirmed against a 6-module HV stack (givenergy-hass#174): FC04 / 0x50 / start 60 / count 60 and the same at 0x51 both decode cleanly through BmuRegisterGetter — 24 cells ~3.30 V, 24 temperatures ~36.5 °C, and distinct per-module serials at each address (proving the separate-address layout, not a single echoed cache).

Grid protection (HR63–83)

The installer HOLD_REGISTER enum confirms the library's HR63–83 addresses exactly (HR63 VAC_LOW_PROTECT_OUT_VALUE … HR83 VOLTAGE_PROTECTION_10_MINUTES). The deci-V / centi-Hz scales are corroborated by the app's measured-quantity decodes (AC_VOLTAGE ÷10, FAC ÷100). GE's structure is three functions, not three severity levels: trip (HR63–70), reconnect band (HR71–78), grid band (HR79–82). Per-grid-code limit values are firmware-managed (not in the app); the grid code itself is written as a packed [safetyStandard, region] u16 to HR2.

Destructive operations / footguns

All bare FC06, gated only in the UI:

Operation Register / value
Factory reset and restart inverter reg163 = 100 (firmware distinguishes by state)
Reset user info reg162
SOC calibration reg29 (0=off … 6=set-full-capacity, 7=finish)
Off-grid / black-start (3-phase) OFF_GRID_ENABLE 1105 + nominal V 1106 / Hz 1107

Using the inventory file

installer_1.154.3_inventory.json:

  • register_maps — 27 maps (HOLD_REGISTER, INPUT_REGISTER, THREE_PHASE_*, EMS_*, HV_BCU/BMU/BAMS_*, PCS_*, METER_*, GATEWAY_*, DATALOG_*, the BMS cluster-detail V/T blocks). Each map is {count, registers: {number: {name, scale?}}} — iterate register_maps[map].registers keyed by register address (count is the integrity check). scale carries divide_by / signed / byte_count / offset where the app defines one (231 registers across the maps).
  • enums — 68 code/value/bitfield enums: DEVICE_TYPE_CODE + the per-family *_MODEL tables, SAFETY_STANDARD, BATTERY_TYPE, SOC_CALIBRATION_SETTING, WORKING_MODE, INVERTER_STATUS, MODBUS_FUNCTION_CODE/ERROR_CODE, the single- and three-phase fault-code bit tables (INVERTER_FAULT_CODE, THREE_PHASE_HYBRID_FAULT_CODE_WORD_0..7), BATTERY_FAULT_CODE, BMS_*_ALARM, etc. A few enums whose own name wasn't recoverable carry a ?-suffixed inferred label.

Reconciliation notes for the library

  • The inverter.py "skip" zones are now decoded as raw read-back (scales app-unconfirmed, the HR300-359 posture): HR84–93 (ISO/GFCI/DCI protection), HR99–107 (string/grid voltage + power adjustments), HR129–156 (PF-curve / CEI021 / LVFRT). Left undecoded: HR157–161 (unnamed in the installer map), HR162 RESET_USER_INFORMATION (momentary write-trigger), and HR115 (the installer's IS_LAN contradicts the old island_check_continue guess — unconfirmed).
  • HR101–104 are address-reused across product lines. The installer's single shared (three-phase-centric) name table calls them GRID_R/S/T_VOLTAGE_ADJUSTMENT + GRID_POWER_ADJUSTMENT — the per-line-phase meaning. On single-phase hardware the firmware repurposes them, and both the consumer app v4.0.7 and the library's own write surface agree on the 1ph semantics: grid_import_limit (101), grid_import_limit_enabled (102), enable_lora (103), enable_battery_self_heating (104, app type=boolean). So SinglePhaseInverter decodes the 1ph names and ThreePhaseInverter overrides the four with the R/S/T names. Naming the read fields to match the write surface (GRID_IMPORT_LIMIT / _ENABLED) also makes read-after-write consistent. Values read 0x0000 on an unconfigured single-phase capture, so they aren't yet wire-confirmed.
  • The fault bit tables (currently britkat-sourced, "not verified") are validated against GE's enums once the MSB-first vs LSB-first convention is accounted for — with one real fix: bit 11 is the Hall current sensor, not "Hail Sensor".
  • BATTERY_FAULT_CODE decodes the single-phase inverter's IR(57) (the library's raw charger_warning_code) — a 16-bit storage-warning word, now surfaced decoded as charger_warning_messages. The meter-comms bit (15) confirms it is an inverter-level word, not a battery-pack register.
  • BCU_STATUS decodes the HV BCU's IR(70) (status → typed status_label). The BCU's polled IR(107–119) diagnostic tail (fan_fault_code, self_check_status, pack_warning/protection/ fault_status) is now surfaced as raw read-back — bit-level semantics are not yet enum-confirmed.
  • BMS_LEVEL_ALARM / BMS_MAINTENANCE_ALARM belong to the bms_cluster device band (0x20+), which the library does not model; the extract carries no device/function-code/start metadata for those maps, so decoding them needs a new device model plus a wire capture. Tracked as follow-up.
  • EMS names HR111/112 BATTERY_*_MAX_C_RATING — confirming they're a %-of-rated C-rating ceiling.
  • HR199: the app's generic MODE_ENABLE_SWITCH vs the library's enable_inverter_parallel_mode — worth verifying against a real single-phase capture before any rename.

Provenance caveat: this is GE's own installer tooling, the best non-hardware source — but the app can carry its own mislabels/typos (e.g. GRID_VOLTAGE_FALUT). Treat as authoritative-pending a wire capture, not gospel.