Register identification

Register identification via sentinel cross-correlation

The GivEnergy Android app's Read Only tab displays telemetry labels (e.g. "Grid voltage 242.7 V", "Battery temperature 25.0 °C") but does not show register numbers. This document describes how to identify the register address backing each label using the MockPlant sentinel approach.

Principle

Seed a MockPlant with sentinel values — raw register value = register address. When the app reads a register and applies its converter (e.g. divide by 10 for "deci" scale), it displays a value that encodes the address. Reading that value off the screen and inverting the converter recovers the address.

For a linear converter with scale s:

raw = address
displayed = address × s

Single-pass ambiguity: the same displayed value can match multiple (address, scale) pairs. For example 24.2 matches both address 242 at scale 0.1 and address 2420 at scale 0.01.

Two-pass resolution: run a second pass with offset=K (e.g. 1000):

pass 1:  d1 = address × s
pass 2:  d2 = (address + K) × s

s = (d2 − d1) / K          ← scale, uniquely determined
address = d1 / s            ← address, uniquely determined

Step-by-step procedure

1. Choose the register banks to probe

Decide which device address and register type to seed. For inverter telemetry:

Bank Device Type
Standard inverter IR 0x31 IR
Holding registers 0x11 HR
Battery 0x32–0x37 IR

Seed ranges densely (e.g. range(0, 240)) so the app's read requests always find populated registers and don't time out.

2. Run pass 1 (offset = 0)

# Using givenergy-cli (once the identify commands are implemented):
givenergy-cli mock-plant \
    --capture path/to/plant.log \
    --sentinels \
    --device 0x31 --type ir --base 0 --count 240 \
    --offset 0 \
    --host 0.0.0.0 --port 8899

# Or directly in Python:
from givenergy_modbus.testing import MockPlant
from givenergy_modbus.model.register import IR

mock = MockPlant.from_sentinels(
    "path/to/plant.log",
    spec=[(0x31, IR, range(0, 240))],
    offset=0,
)
import asyncio
asyncio.run(mock.serve_forever())

Connect the GivEnergy app to the mock's IP and port. Navigate to Direct Control → Read Only. For each displayed label, record the value as d1.

3. Run pass 2 (offset = 1000)

Stop the mock; re-start with --offset 1000. Record each value as d2.

Choosing K: use K = 1000. This is safe for all known GivEnergy register addresses (max address ≈ 5014; 5014 + 1000 = 6014 ≪ 65535 uint16 max).

4. Identify each register

# CLI:
givenergy-cli identify 242.7 --second 342.7 --k 1000
# → address=2427, scale=0.1 (deci), confidence=two-pass

# Python:
from givenergy_modbus.testing import identify
candidates = identify(242.7, 342.7, k=1000)
print(candidates)
# → [Candidate(address=2427, scale=0.1, confidence='two-pass')]

5. Cross-check against the existing model

Compare each (address, scale) against the existing register LUT (SinglePhaseInverterRegisterGetter.REGISTER_LUT in model/inverter.py).

  • Address matches an existing Def → confirm the app label is the human-readable name for that field. Update the field's comment/docstring if it differs.
  • Address unknown → record it as a new Def candidate for the #48 register audit. Note the app label and inferred scale; submit a PR adding Def(C.deci, None, IR(address)) (or the appropriate converter) under the right field name.

6. Handle clamping and non-linear registers

Some fields are problematic for auto-identification:

Case Symptom Workaround
Clamped field (e.g. SOC %) App shows 100.0 % even with sentinel=2427 Use a sentinel value in the valid range; probe with a third pass using a smaller offset
Boolean/enum App shows only 0 or 1 Use a non-zero in-range sentinel and check which field toggles
uint32 pair Two registers combine into one displayed value Seed the two adjacent addresses and note which label changes when each changes
timeslot Two registers encode start/end time Similar to uint32

Non-linear registers cannot be uniquely identified by identify() — handle them manually.

Example mapping table

After completing both passes, build a table like:

App label address type scale Existing field Action
Grid voltage 2427 IR 0.1 (deci) v_ac1 at IR(8) Mismatch — re-probe, likely IR(8) not 2427
Battery temperature 250 IR 0.1 (deci) t_battery at IR(56)
AC charge today ? IR 0.1 (deci) unmapped Add Def(C.deci, None, IR(?))

Note: the sentinel value is the address, not necessarily a realistic reading. "Grid voltage 242.7 V" from a sentinel means address 2427, but the real v_ac1 at address 8 would display 0.8 V in sentinel mode. Use cross-referencing, not absolute values, to confirm names.

Reference

  • givenergy_modbus/testing/identify.pysentinel_devices, identify, Candidate
  • givenergy_modbus/testing/mock_plant.pyMockPlant.from_sentinels
  • givenergy_modbus/model/inverter.pySinglePhaseInverterRegisterGetter.REGISTER_LUT
  • Issue #48 — register audit tracking confirmed and candidate fields